Every number on this page comes from patients the models never saw during training, using 5-fold cross-validation split by patient.
How many malignant nodules are caught (up) for each rate of false alarms (right). A perfect model hugs the top-left corner.
Loading…
Each fold's model is tested on a different fifth of the patients; the spread shows how stable the results are.
3D ResNet (8.3 M parameters, trained from scratch) reads the nodule as a true 3D volume, shown below. 2.5D multi-view CNN (11.2 M parameters) cuts 9 planes through the nodule (3 orthogonal, 6 diagonal), passes each through an ImageNet-pretrained ResNet18, and pools what it sees. Because they look at nodules differently, their mistakes differ, and averaging them helps.
The model learned to predict what radiologists would think about a nodule, not confirmed diagnoses. Its ceiling is their agreement with each other.
LIDC-IDRI scans come from a few US institutions in the 2000s. Scanners, protocols and populations elsewhere differ, and performance may drop there.
The automatic detector finds most nodules but not all, and sometimes flags other structures. A missed nodule gets no score, and anything you click still gets one.
Doctors use growth over time, symptoms, smoking history and other tests. The model sees one 48 mm cube from one scan.